Lighting equipment

LED strip light

Year: 
2016
Week: 
9
Product: 
Self-adhesive LED Strip Warm White
Brand: 

The electrical insulation, and the creepage distances between the primary and secondary windings, of the power supply unit are not sufficient. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standards EN 60598 and EN 61347.

Risk level: 

Desk lamp

Year: 
2016
Week: 
8
Product: 
Flexo Lamp
Brand: 

The internal wiring might become damaged where it passes through metal parts that are unprotected against abrasion. The live conductors could consequently come into contact with accessible metal parts. The mains cable is not properly attached and could come out if accidentally pulled, leaving the live ends of the wires accessible to the user. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Risk level: 

LED floodlight

Year: 
2016
Week: 
7
Product: 
Projecteur à LED 20 W sur Pied
Brand: 

The earth wire is not properly held in place. If it detached, the product would not be earthed. Water can enter the casing. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Risk level: 

Light

Year: 
2016
Week: 
6
Product: 
LED paneelivalaisin / LED Panel Light
Brand: 

The electrical insulation is not sufficient between the windings of the transformer in the power supply unit. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.

Risk level: 

Lamp socket

Year: 
2016
Week: 
5
Product: 
Casquillo E27 Blanco
Brand: 

There is no mechanism to block the screwed cable entry. When the user inserts and removes the bulb several times, the cable will start to screw and unscrew. This can damage the cable, leaving the live conductors accessible. The product does not comply with the requirements of the Low Voltage Directive and the relevant national standard.

Risk level: 

Torch

Year: 
2016
Week: 
8
Product: 
Rechargeable LED Torch
Brand: 

When connecting/ disconnecting the torch to the mains, contact with live parts can occur. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60598.